Search results for "Radius Fractures"
showing 10 items of 18 documents
Complex radial head and neck fractures treated with modern locking plate fixation
2019
Background Internal fixation of complex radial head and neck (CRHN) fractures is difficult, and postoperative complications are common. This study evaluated elbow function and patient clinical status after internal fixation of CRHN fractures with modern locking plates. Methods We included 40 patients with 41 fractures (1 bilateral lesion). In 25 patients (61%), a concomitant injury was found. Patients were an average age of 46 years (range, 22-70 years). The mean follow-up time was 36 months (range, 2-70 months). Postoperative assessments included evaluation of range of motion, functional scores, and radiologic findings. We assessed fracture healing, surgical complications, revision surgery…
Intraoperative C-arm CT imaging in angular stable plate osteosynthesis of distal radius fractures
2013
The purpose of this study was to analyze the practicability and benefit of intraoperative C-arm computed tomography (CT) imaging in volar plate osteosynthesis of unstable distal radius fractures. During a 1 year period, intraoperative three dimensional (3D) imaging with the ARCADIS Orbic 3D was performed in addition to standard fluoroscopy in 51 cases. The volar angular stable plate oesteosyntheses were analyzed intraoperatively and, if necessary, improved immediately. The duration of the scan and radiation exposure dose were measured. On average, performance of the scan and analysis of the CT dataset took 6.7 minutes. In 31.3% of the surgeries a misplacement of screws was detected and cor…
Epidemiology of distal radius fractures in children and adults during the COVID-19 pandemic - a two-center study
2021
Abstract Background Distal radius fractures (DRFs) constitute 15–21% of all fractures. There are no detailed data on the possible changes in the epidemiology and treatment of DRFs in children and adults during the Covid pandemic. The purpose of our study was a comprehensive assessment of the impact of the COVID-19 pandemic on distal radius fractures (DRF) epidemiology, including both children and adults and various fracture fixation methods in two large trauma centers in Poland. Methods This study compared the medical data on the treatment of distal radius fractures in Poland in two periods: the period of the COVID-19 pandemic (from March 15 to October 15, 2020) and the corresponding period…
Are there any differences in various polyaxial locking systems? A mechanical study of different locking screws in multidirectional angular stable dis…
2012
Numerous angular stable plates for the distal radius exist, and technically based comparisons of the polyaxial locking interfaces are lacking. The aim of this mechanical study was to investigate three different locking interfaces of angular stable volar plates by cantilever bending: VA-LCP Two-Column Distal Radius Plates 2.4 mm (Synthes® GmbH, Oberdorf, Switzerland), IXOS® P4 (Martin, Tuttlingen, Germany) and VariAX™ (Stryker®, Duisburg, Germany). We assessed the strength of 0°, 5°, 10° and 15° screw locking angles and tested the bending strength from 10° to 5° angles by cyclic loading until breakage. The final setup repeated the above assessments by inclusion of four locking screws. The si…
Management of Distal Radius Fractures in the Elderly Patients
2015
Distal radius fractures are one of the most common injuries treated by the orthopedic surgeons representing almost 1/6 of the fractures that are treated in the emergency departments and the 75% of all fractures of the upper limb and are second only to hip fractures in elderly population. The age distribution of this kind of injury is typically bimodal with peaks in the young patients (6-25) and in the elderly patients older than 65. In the first case the mechanism of injury is usually a high energy trauma, such as a car accident, whilst in the second one is usually a low energy trauma like a domestic fall. Various classification systems have been proposed for these fractures. The classic ep…
The Epidemiology of Low- and High-Energy Distal Radius Fracture in Middle-Aged and Elderly Men and Women in Southern Norway
2012
Background Distal radius is one of the most frequent sites for fractures in the elderly population. Despite this, there is a paucity of epidemiological data for distal radius fracture, in particular, distinguishing between high- and low-energy fractures. Our aim was to study the epidemiology of high- and low-energy distal radius fracture in middle-aged and elderly men and women in Southern Norway, and search for associates with high- or low-energy distal radius fracture in this population. Methodology/Principal Findings Patients with distal radius fractures aged ≥50 years were identified from all four hospitals in Southern Norway between 2004 and 2005. Age-adjusted and age-specific incidenc…
Volar Fixed-Angle Plating of Distal Radius Fractures
2011
The purpose of this biomechanical study was to determine whether a multidirectional fixed-angle plate with locking screws or with locking pegs in the distal fragment would optimize fixation of Orthopaedic Trauma Association (OTA) type A3 distal radius fractures.Eight pairs of fresh-frozen human distal radii were used. Extra-articular distal radius fractures were created and stabilized with a multidirectional volar fixed-angle plate. The radii were randomized into 2 matched-paired groups. The distal fragment in Group I was stabilized with 7 locking screws. The distal fragment in Group II was fixed with 7 locking pegs. The proximal fragment in both groups was fixed with 3 screws. The specimen…
The functional and radiographic outcomes following distal radius fracture treatment in a cast for 4 and 6 weeks in the elderly: A randomized trial.
2022
Background. The optimal duration of cast immobilization following distal radius fractures (DRFs) in elderly patients has not been established. Objectives. To assess the functional and radiological parameters following DRF treatment in elderly patients using 2 different periods of cast immobilization. Materials and methods. We assessed 50 patients (33 women and 17 men). The mean age at the beginning of treatment was 71 years. The mean duration of follow-up was 1 year and 3 months. One subgroup (n = 26) included patients treated with a cast for 4 weeks, whereas the other subgroup (n = 24) included patients treated with a cast for 6 weeks. The following measures were assessed: union rate, radi…
Low bone mineral density is a significant risk factor for low-energy distal radius fractures in middle-aged and elderly men: A case-control study
2011
Abstract Background In general there is a lack of data on osteoporosis and fracture in men; this also includes low-energy distal radius fractures. The objectives of this study were to examine BMD and identify factors associated with distal radius fractures in male patients compared with controls recruited from the background population. Methods In a 2-year period, 44 men 50 years or older were diagnosed with low-energy distal radius fractures, all recruited from one hospital. The 31 men who attended for osteoporosis assessment were age-matched with 35 controls. Demographic and clinical data were collected and BMD at femoral neck, total hip and spine L2-4 was assessed by dual energy X-ray ab…
Mid- to long-term results after bipolar radial head arthroplasty.
2009
Background Radial head arthroplasty is considered the treatment of choice for unreconstructable radial head fractures in the acute fracture situation. Although short-term results in the current literature are promising, replacement of the radial head remains controversial as long-term results are still missing. We report our 8.8-year results after treatment with a bipolar radial head prosthesis by Judet. Materials and methods In our department, 19 patients were treated with bipolar radial head arthroplasty between 1997 and 2001. Seventeen of these patients—14 men and 3 women—were examined retrospectively after 106 months (range, 78-139). Of these, 9 patients were treated primarily, 7 patien…